![]() 7.1.3 Connecting the service PC to the BV family system The service PC can be connected with a cross cable to the BV Family system. The Internet Protocol (TCP/IP) Properties window appears. Enter the IP address (use the Service IP address (see Setup tab on the MVS), change the last digit group to another number than visible on the MVS, e.g. The Advanced TCP/IP Settings window appears. Mark and select Internet Protocol (TCP/IP). The Local Area Connection Properties window appears. Click with the right mouse button on the Local Area Connection icon. Double click the Network (and Dail-up) icon. ![]() 7.1.4 Configuring a service connection with a cross cable The settings for the network are described for a Windows 2000 and XP operating system. Figure 1 Connecting the service PC to the BV Family system (ViewForum and DICOM are optional) Cable Connector Access to BV-Scope possible? Performing of DICOM functions possible? Downloading of software Type of connection Cross cable Ethernet Yes Yes Yes (about 2 min.) Local (point to point) Table 1 Connection between the service PC and the BV Family system For the necessary configuration of the connection and the preparation of the service PC for BV-Scope, see the next chapters. In case of integrated DICOM functionality: contact the network administrator for an IP address for the service PC.(Usually this can be done by selecting: Programs > PMS Service Work Bench > Security Toolbox.Start the Security toolbox to check this.A connected hardware key level 0 for X-ray or IST level 0 account with known password.Windows 2000 or XP with administrator rights.7.1.2 Requirements of the service PC The requirements for the service PC are: WARNING Together with a restart of the system, always close BV-Scope and restart it. WARNING After adjustments of the system always restart the system to ensure, the new adjustments will be activated. Next, the BV-Scope menu items that are available to BV-Scope administrators (with authorization level "A") are described. would need to know software version to know for sure 7.1 Service PC 7.1.1 Introduction This chapter describes how to configure a connection between the service PC and the BV Family system. if you do not have enable service you have a very old system that requires a parallel dongle most likely. Per the manual I have it does not say db9 to db25 it says network crossover.if there was an email address I would send you the manual. Re: re: re: Philips Libra X-Scope Connection
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |